{"id":9259,"date":"2026-10-14T18:53:21","date_gmt":"2026-10-14T18:53:21","guid":{"rendered":"https:\/\/directmacro.com\/blog\/?p=9259"},"modified":"2026-10-14T18:57:20","modified_gmt":"2026-10-14T18:57:20","slug":"arista-7050qx-32s-review","status":"publish","type":"post","link":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review","title":{"rendered":"Arista 7050QX-32S Review (DCS-7050QX-32S-R): 40GbE Switch Specification and Deployment"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1191.75px;margin-left: calc(-5% \/ 2 );margin-right: calc(-5% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:2.375%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:2.375%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:2.375%;--awb-spacing-left-medium:2.375%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:2.375%;--awb-spacing-left-small:2.375%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [{\n    \"@type\": \"Question\",\n    \"name\": \"What is the Arista DCS-7050QX-32S-R?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"It is a 1RU Arista 7050QX-32S data center switch with 32 x 40GbE QSFP+ ports, 4 x 10GbE SFP+ ports, dual 500W AC power supplies, and rear-to-front airflow.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What is the Arista 7050QX-32S throughput and latency?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Arista 7050QX-32S throughput is 2.56 Tbps with 1.44 billion packets per second, and Arista 7050QX-32S latency starts at 550 nanoseconds in cut-through mode.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Does the Arista 7050QX-32S support 10GbE?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. You can split up to 24 QSFP+ ports into 4 x 10GbE each for 96 x 10GbE ports, and the four SFP+ ports support 1GbE and 10GbE.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"What does the -R in DCS-7050QX-32S-R mean?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"The -R suffix means rear-to-front airflow. Choose it when the switch ports face the hot aisle, and choose the -F model when ports face the cold aisle.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Is the Arista 7050QX-32S good for leaf spine networks?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Arista 7050QX-32S leaf spine designs commonly use it as a 10\/40GbE leaf or a compact 40GbE spine with BGP, MLAG, and VXLAN.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Is a refurbished Arista 7050QX-32S reliable?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"A tested refurbished unit with both power supplies, all fans, verified ports, and a warranty is a reliable, cost-effective choice for production, spares, and labs.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Is the Arista 7050QX-32S end of life?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Arista stopped selling it on December 13, 2022, and 24x7 TAC support, hardware RMA, and end of life followed on December 13, 2025. Tested refurbished units are still widely available with reseller warranties.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Which EOS version should I run on the 7050QX-32S?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"EOS 4.28 is the final software train that supports the 7050X Series, because EOS 4.29 and later drop the platform. Run the newest 4.28 release you are entitled to and keep one version across the fabric.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Is the Arista 7050QX-32S loud?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Yes. Like most 1RU data center switches, it uses high-speed fans that are very loud at startup and noticeable under load. Install it in a server room or data center rack, not an office.\"\n    }\n  },{\n    \"@type\": \"Question\",\n    \"name\": \"Does the Arista 7050QX-32S need licenses for BGP and VXLAN?\",\n    \"acceptedAnswer\": {\n      \"@type\": \"Answer\",\n      \"text\": \"Often, yes. Arista's datasheet lists separate Group 2 feature licenses: LIC-FIX-2-E for Enhanced L3 (BGP, OSPF, IS-IS, PIM), LIC-FIX-2-V for VXLAN and VM Tracer, and LIC-FIX-2-Z for ZTP, LANZ, and OpenFlow. Ask the seller which licenses a refurbished unit includes before you buy.\"\n    }\n  }]\n}\n<\/script><div class=\"fusion-content-boxes content-boxes columns row fusion-columns-1 fusion-columns-total-1 fusion-content-boxes-1 content-boxes-icon-with-title content-left .table-of-content-wrapper\" style=\"--awb-item-margin-top:1px;--awb-item-margin-bottom:1px;--awb-margin-top:1px;--awb-margin-bottom:1px;--awb-hover-accent-color:var(--awb-color7);--awb-circle-hover-accent-color:var(--awb-color7);\" data-animationOffset=\"top-into-view\"><div style=\"--awb-backgroundcolor:rgba(255,255,255,0);\" class=\"fusion-column content-box-column content-box-column content-box-column-1 col-lg-12 col-md-12 col-sm-12 fusion-content-box-hover content-box-column-last content-box-column-last-in-row\"><div class=\"col content-box-wrapper content-wrapper link-area-box content-icon-wrapper-yes icon-hover-animation-none\" data-animationOffset=\"top-into-view\"><div class=\"heading heading-with-icon icon-left\"><div class=\"icon\"><span style=\"height:42px;width:42px;line-height:22px;border-color:rgba(255,255,255,0);border-width:1px;border-style:solid;background-color:var(--awb-color8);box-sizing:content-box;border-radius:50%;\"><i style=\"border-color:var(--awb-color8);border-width:1px;background-color:var(--awb-color7);box-sizing:content-box;height:40px;width:40px;line-height:40px;border-radius:50%;position:relative;top:auto;left:auto;margin:0;border-radius:50%;font-size:20px;\" aria-hidden=\"true\" class=\"fontawesome-icon fa-list-ul fas circle-yes\"><\/i><\/span><\/div><p class=\"content-box-heading\" style=\"--body_typography-font-size:24px;line-height:29px;\">Table of Contents<\/p><\/div><div class=\"fusion-clearfix\"><\/div><div class=\"content-container\">\r\n<hr \/>\r\n<\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><div class=\"awb-toc-el awb-toc-el--1\" data-awb-toc-id=\"1\" data-awb-toc-options=\"{&quot;allowed_heading_tags&quot;:{&quot;h2&quot;:0},&quot;ignore_headings&quot;:&quot;&quot;,&quot;ignore_headings_words&quot;:&quot;&quot;,&quot;enable_cache&quot;:&quot;yes&quot;,&quot;highlight_current_heading&quot;:&quot;no&quot;,&quot;hide_hidden_titles&quot;:&quot;yes&quot;,&quot;limit_container&quot;:&quot;post_content&quot;,&quot;select_custom_headings&quot;:&quot;&quot;,&quot;icon&quot;:&quot;fa-angle-double-right fas&quot;,&quot;counter_type&quot;:&quot;custom_icon&quot;}\" style=\"--awb-margin-bottom:1px;--awb-item-font-family:&#039;Bookman Old Style&#039;, serif;--awb-item-font-style:italic;--awb-item-font-weight:700;--awb-item-overflow:hidden;--awb-item-white-space:nowrap;--awb-item-text-overflow:ellipsis;\"><div class=\"awb-toc-el__content\"><\/div><\/div><div class=\"fusion-text fusion-text-1\"><h2>Key Takeaways<\/h2>\n<ul>\n<li>The Arista 7050QX-32S 40GbE switch delivers 2.56 Tbps and 1.44 billion packets per second across 32 QSFP+ ports in 1RU.<\/li>\n<li>Arista 7050QX-32S latency starts at 550 nanoseconds in cut-through mode, which suits trading, HPC, and east-west application traffic.<\/li>\n<li>Breakout support gives up to 96 x 10GbE plus 8 x 40GbE, and four SFP+ ports connect 1GbE or 10GbE devices directly.<\/li>\n<li>Arista 7050QX-32S EOS brings MLAG, VXLAN, eAPI automation, and LANZ congestion monitoring to every deployment.<\/li>\n<li>The DCS-7050QX-32S-R rear-to-front airflow model must match your hot-aisle and cold-aisle layout before you buy.<\/li>\n<li>This Arista 7050QX-32S review finds that tested refurbished units deliver enterprise 40GbE performance at a fraction of the original price, making them ideal for labs, spares, and leaf layers.<\/li>\n<\/ul>\n<h2>Overview<\/h2>\n<p>Your servers run 10GbE and 40GbE, your storage traffic keeps growing, and a new 100GbE fabric costs more than your budget allows. The <a href=\"https:\/\/directmacro.com\/manufacturers\/arista.html\" target=\"_blank\" rel=\"noopener\">Arista<\/a> <a href=\"https:\/\/directmacro.com\/arista-networks-dcs-7050qx-32s-r.html\" target=\"_blank\" rel=\"noopener\">DCS-7050QX-32S-R<\/a> closes that gap. It packs 32 QSFP+ ports and four SFP+ ports into one rack unit and moves 2.56 Tbps at wire speed, with latency from 550 nanoseconds.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9261 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview.jpg\" alt=\"7050QX-32S Overview\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/7050QX-32S-Overview.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>We wrote this Arista 7050QX-32S review for network engineers, data center architects, and IT managers who want proven Arista performance at a refurbished price. The switch runs the same EOS software as Arista&#8217;s current platforms, so your team keeps the MLAG, VXLAN, BGP, and automation tools it already knows.<\/p>\n<p>Below, we cover performance, use cases, deployment, end-of-life status, and the checks to make before you buy, so you can decide quickly whether this switch belongs in your rack.<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><h2>Arista 7050QX-32S Review: Quick Verdict<\/h2>\n<p>Our short Arista DCS-7050QX-32S-R review verdict: this is one of the most cost-effective ways to build a 40GbE fabric today. Arista designed the Arista 7050QX-32S data center switch as a high-density leaf or compact spine in the Arista 7050X family, and it still handles modern virtualization, storage, and analytics traffic at wire speed. Its main limits come with age. It has no native 25GbE or 100GbE ports, and Arista lists December 13, 2025 as its end-of-life date, with EOS 4.28 as the last supported software train, so plan on reseller warranty coverage rather than Arista TAC support.<\/p>\n<p>If your servers use 10GbE or 40GbE NICs, this Arista 7050QX-32S review rates the switch as excellent value per port. If you are planning a 25\/100GbE refresh within the next 12 months, look at newer platforms instead.<\/p>\n<p><strong>Ready to Order? <\/strong>Direct Macro keeps tested DCS-7050QX-32S-R units in stock and ready to ship. Order a single switch, an MLAG pair, or a pair plus a spare, and lock in refurbished pricing before stock runs low.<\/p>\n<h2>Arista 7050QX-32S Pros and Cons<\/h2>\n<p>Here is a quick summary from this Arista 7050QX-32S review of where the switch shines and where it falls short for today&#8217;s buyers.<\/p>\n<h3>Pros<\/h3>\n<p>Buyers choose the DCS-7050QX-32S-R for five practical reasons, and each one comes straight from Arista&#8217;s datasheet and real data center deployments:<\/p>\n<ul>\n<li><strong>Wire-Speed Density:<\/strong> 32 x 40GbE, or 96 x 10GbE plus 8 x 40GbE, at full line rate in a single rack unit.<\/li>\n<li><strong>Sub-Microsecond Latency:<\/strong> Cut-through forwarding from 550ns suits trading, HPC, and storage traffic.<\/li>\n<li><strong>Mature EOS Features:<\/strong> MLAG, VXLAN, BGP, eAPI, and LANZ are all supported, although BGP, VXLAN, and LANZ require EOS feature licenses.<\/li>\n<li><strong>Low Cost per Port:<\/strong> Refurbished pricing makes 40GbE far cheaper than new 100GbE hardware.<\/li>\n<li><strong>Efficient and Redundant:<\/strong> About 5W per 40GbE port, 1+1 hot-swap power supplies, and hot-swap fans.<\/li>\n<\/ul>\n<h3>Cons<\/h3>\n<p>No switch fits every network. Before you order, weigh these five limitations, most of which come from the platform&#8217;s age and end-of-life status:<\/p>\n<ul>\n<li><strong>End of Life:<\/strong> Arista TAC support, hardware RMA, and software bug fixes have all ended.<\/li>\n<li><strong>Software Ceiling:<\/strong> EOS 4.28 is the final supported train, so newer EOS features will not arrive.<\/li>\n<li><strong>No 25\/100GbE:<\/strong> There is no native support for 25GbE servers or 100GbE uplinks.<\/li>\n<li><strong>Loud Fans:<\/strong> Data center fans make it too noisy for offices or home labs without a separate room.<\/li>\n<li><strong>Shared SFP+ Ports:<\/strong> The four SFP+ ports share the first QSFP+ port, which limits port planning.<\/li>\n<\/ul>\n<\/div><div class=\"fusion-text fusion-text-3\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Arista 7050QX-32S Specifications<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9262 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications.jpg\" alt=\"Arista 7050QX-32S Specifications\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Specifications.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>The table below summarizes the core Arista 7050QX-32S specifications from Arista&#8217;s published datasheet for this model.<\/p>\n<p>&nbsp;<\/p>\n<figure class=\"wp-block-table is-style-stripes\">\n<table>\n<thead>\n<tr>\n<th>Specification<\/th>\n<th>Arista DCS-7050QX-32S-R<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Model \/ Series<\/strong><\/td>\n<td>DCS-7050QX-32S-R, Arista 7050X Series<\/td>\n<\/tr>\n<tr>\n<td><strong>Ports<\/strong><\/td>\n<td>32 x 40GbE QSFP+ and 4 x 10GbE SFP+ (SFP+ ports shared with the first QSFP+ port)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max 40GbE Ports<\/strong><\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td><strong>Max 10GbE Ports<\/strong><\/td>\n<td>96 (24 QSFP+ ports in 4 x 10GbE breakout, plus 8 x 40GbE)<\/td>\n<\/tr>\n<tr>\n<td><strong>Max 1GbE Ports<\/strong><\/td>\n<td>4 (SFP+)<\/td>\n<\/tr>\n<tr>\n<td><strong>Throughput<\/strong><\/td>\n<td>2.56 Tbps<\/td>\n<\/tr>\n<tr>\n<td><strong>Forwarding Rate<\/strong><\/td>\n<td>1.44 billion packets per second (1440 Mpps)<\/td>\n<\/tr>\n<tr>\n<td><strong>Latency<\/strong><\/td>\n<td>550 to 650 ns in cut-through mode<\/td>\n<\/tr>\n<tr>\n<td><strong>Forwarding<\/strong><\/td>\n<td>Wire-speed Layer 2 and Layer 3<\/td>\n<\/tr>\n<tr>\n<td><strong>Packet Buffer<\/strong><\/td>\n<td>12MB shared, with Dynamic Buffer Allocation of up to 6.7MB per port<\/td>\n<\/tr>\n<tr>\n<td><strong>CPU<\/strong><\/td>\n<td>Quad-core x86<\/td>\n<\/tr>\n<tr>\n<td><strong>System Memory<\/strong><\/td>\n<td>4GB DRAM<\/td>\n<\/tr>\n<tr>\n<td><strong>Flash Storage<\/strong><\/td>\n<td>4GB<\/td>\n<\/tr>\n<tr>\n<td><strong>SSD Storage<\/strong><\/td>\n<td>Optional 120GB, factory-fitted only on the DCS-7050QX-32S-D#; not included with the -R<\/td>\n<\/tr>\n<tr>\n<td><strong>Management Ports<\/strong><\/td>\n<td>1 x 10\/100\/1000 management, 1 x RS-232 serial (RJ-45), 1 x USB<\/td>\n<\/tr>\n<tr>\n<td><strong>MAC Addresses<\/strong><\/td>\n<td>32K in base mode; up to 288K in UFT modes<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv4 Hosts<\/strong><\/td>\n<td>16K in base mode; up to 208K in UFT modes<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv4 Unicast Routes<\/strong><\/td>\n<td>16K in base mode; up to 144K in UFT modes<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv6 Hosts<\/strong><\/td>\n<td>16K in base mode; up to 104K in UFT modes<\/td>\n<\/tr>\n<tr>\n<td><strong>IPv6 Unicast Routes<\/strong><\/td>\n<td>8K in base mode<\/td>\n<\/tr>\n<tr>\n<td><strong>IGMP Groups<\/strong><\/td>\n<td>288K, with 8K unique groups<\/td>\n<\/tr>\n<tr>\n<td><strong>VLANs<\/strong><\/td>\n<td>4,096 (IEEE 802.1Q), plus Q-in-Q<\/td>\n<\/tr>\n<tr>\n<td><strong>Spanning Tree<\/strong><\/td>\n<td>802.1w RSTP, 802.1s MSTP, RPVST+; 64 MST \/ 510 RPVST+ instances<\/td>\n<\/tr>\n<tr>\n<td><strong>ACLs<\/strong><\/td>\n<td>4K ingress, 1K egress; IPv4, IPv6, and MAC ACLs<\/td>\n<\/tr>\n<tr>\n<td><strong>Link Aggregation<\/strong><\/td>\n<td>802.3ad LACP, 64 ports per channel, 104 groups per system<\/td>\n<\/tr>\n<tr>\n<td><strong>MLAG<\/strong><\/td>\n<td>Up to 64 ports per MLAG<\/td>\n<\/tr>\n<tr>\n<td><strong>ECMP<\/strong><\/td>\n<td>64-way, 1K groups<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:post-content --><\/p>\n<p>&nbsp;<\/p>\n<\/div>\r\n<!-- wp:table {\"className\":\"is-style-stripes\"} -->\r\n<figure class=\"wp-block-table is-style-stripes\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Specification<\/th>\r\n<th>Arista DCS-7050QX-32S-R<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><strong>Routing Protocols<\/strong><\/td>\r\n<td>OSPF, OSPFv3, BGP, MP-BGP, IS-IS, RIPv2, PIM-SM\/SSM\/BIDIR, VRRP, BFD, VRF, PBR<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Virtualization<\/strong><\/td>\r\n<td>VXLAN routing, bridging, and gateway; VM Tracer for VMware vSphere<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>QoS<\/strong><\/td>\r\n<td>8 queues per port, strict priority, WRR, PFC, DCBX, ECN, policing and shaping<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Monitoring<\/strong><\/td>\r\n<td>LANZ, DANZ mirroring, sFlow, 4 active mirror sessions, tcpdump on the switch<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Automation<\/strong><\/td>\r\n<td>Zero Touch Provisioning, eAPI, CloudVision, Python, Bash, AEM<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Time Sync<\/strong><\/td>\r\n<td>IEEE 1588 PTP (transparent and boundary clock)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Security<\/strong><\/td>\r\n<td>TACACS+, RADIUS, SSHv2, Control Plane Protection, DHCP snooping, MAC security<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Jumbo Frames<\/strong><\/td>\r\n<td>Up to 9,216 bytes<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Feature Licenses<\/strong><\/td>\r\n<td>Group 2: LIC-FIX-2-E (Enhanced L3), LIC-FIX-2-V (Virtualization), LIC-FIX-2-Z (Monitoring and Provisioning), LIC-FIX-2-FLX-L (FLX-Lite)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Power Supplies<\/strong><\/td>\r\n<td>2 x hot-swap 500W AC (1+1 redundant); 500W DC option<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>PSU Input<\/strong><\/td>\r\n<td>100 to 240VAC, 50\/60Hz, IEC 320-C13, 6.3 to 2.2A typical<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>PSU Efficiency<\/strong><\/td>\r\n<td>93% typical (Platinum rated)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Power Draw<\/strong><\/td>\r\n<td>150W typical \/ 302W maximum (typical measured at 25\u00b0C and 50% load)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Fans<\/strong><\/td>\r\n<td>4 hot-swap fans (N+1 redundant)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Airflow<\/strong><\/td>\r\n<td>Rear-to-front (-R); front-to-rear on -F models<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Dimensions (W x H x D)<\/strong><\/td>\r\n<td>19 x 1.75 x 16 in (48.3 x 4.4 x 40.64 cm), 1RU<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Weight<\/strong><\/td>\r\n<td>20 lb (9.1 kg)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Rack Mounting<\/strong><\/td>\r\n<td>Tool-less rails; optional 2-post kit (KIT-2POST-1U-NT)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Operating Temperature<\/strong><\/td>\r\n<td>0 to 40\u00b0C (32 to 104\u00b0F)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Storage Temperature<\/strong><\/td>\r\n<td>-40 to 70\u00b0C (-40 to 158\u00b0F)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Relative Humidity<\/strong><\/td>\r\n<td>5 to 95%<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Operating Altitude<\/strong><\/td>\r\n<td>0 to 10,000 ft (0 to 3,000 m)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Safety and Emissions<\/strong><\/td>\r\n<td>UL\/CSA 60950-1, EN 62368-1, FCC, EN55032, EN55024; RoHS and WEEE<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n<!-- \/wp:table -->\r\n<p>&nbsp;<\/p>\r\n<!-- wp:table {\"className\":\"is-style-stripes\"} -->\r\n<figure class=\"wp-block-table is-style-stripes\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Specification<\/th>\r\n<th>Arista DCS-7050QX-32S-R<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td><strong>Software<\/strong><\/td>\r\n<td>Arista EOS; minimum release 4.14.0, final supported train EOS 4.28<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Original Warranty<\/strong><\/td>\r\n<td>1-year limited hardware warranty from Arista<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Lifecycle<\/strong><\/td>\r\n<td>End of sale December 13, 2022; end of life December 13, 2025<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><strong>Spare Parts<\/strong><\/td>\r\n<td>FAN-7000-R fan module, PWR-500AC-R power supply (rear-to-front)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n<!-- \/wp:table -->\r\n<p>In short, the Arista 7050QX-32S 32 port switch gives you dense QSFP+ connectivity, redundant power, and a capable x86 control plane in a single rack unit. These figures also make it easy to plan power and cooling, since typical draw stays near 150W.<\/p>\r\n<div class=\"fusion-text fusion-text-4\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Arista 7050QX-32S Features<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9265 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features.jpg\" alt=\"Arista 7050QX-32S Features\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Features.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>Specifications sheets only tell part of the story. In this Arista 7050QX-32S review, these are the features from Arista&#8217;s datasheet that matter most once you rack the switch and put it into service.<\/p>\n<h3>1. Unified Forwarding Table and Wire-Speed Layer 3<\/h3>\n<p>Instead of fixed-size tables, the 7050X platform uses a Unified Forwarding Table that you can tune for your design. Base mode provides 32K MAC addresses and 16K IPv4 routes, while UFT modes shift resources to as many as 288K MAC entries, 208K IPv4 host routes, or 144K IPv4 routes. Routing support covers OSPF, OSPFv3, BGP, MP-BGP, IS-IS, VRFs, BFD, VRRP, Virtual ARP, PIM, policy-based routing, and uRPF.<\/p>\n<h3>2. High Availability and Self-Healing Software<\/h3>\n<p>The switch pairs 1+1 hot-swap power supplies with four N+1 hot-swap fans, all color coded to show airflow direction. In software, Stateful Fault Repair restarts failed EOS processes without a reboot, live patching fixes some issues in place, and Smart System Upgrade and Accelerated Software Update reduce maintenance downtime. MLAG supports up to 64 ports per group for active-active Layer 2 multipathing.<\/p>\n<h3>3. Cloud Networking and Virtualization<\/h3>\n<p>VXLAN routing, bridging, and gateway functions connect virtualized workloads to traditional Layer 2 and Layer 3 networks at wire speed, including servers, firewalls, and load balancers that do not support VXLAN. VM Tracer integrates with VMware vSphere, and OpenFlow 1.0 and 1.3, Arista Direct Flow, eAPI, and OpenStack Neutron support give automation teams several ways to program the switch.<\/p>\n<h3>4. Monitoring and Visibility<\/h3>\n<p>LANZ reports microbursts and congestion in real time, while DANZ advanced mirroring, sFlow, and up to four active port-mirror sessions provide network-wide visibility. You can mirror traffic to EOS or the optional SSD and analyze it with tcpdump on the switch itself, and the Advanced Event Management suite automates responses to events. IEEE 1588 PTP transparent and boundary clock support helps timing-sensitive environments such as trading.<\/p>\n<h3>5. QoS and Security<\/h3>\n<p>Each port supports up to eight queues with strict priority and weighted round robin scheduling, plus Priority Flow Control, DCBX, and ECN for lossless storage traffic. Security features include ingress and egress ACLs on Layer 2 to Layer 4 fields, control plane protection, DHCP snooping, TACACS+, RADIUS, SSHv2, and SNMPv3.<\/p>\n<h3>6. Design, Build and Serviceability<\/h3>\n<p>The chassis measures 19 x 1.75 x 16 inches and weighs 20 lb, and it ships with tool-less rails for fast installation, with 2-post and 4-post rail kits available. Airflow is reversible through the choice of fan modules and power supplies, a blue beacon LED helps identify the switch in a crowded rack, and the USB port can restore and configure the switch from a flash drive.<\/p>\n<\/div><div class=\"fusion-text fusion-text-5\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Arista 7050QX-32S Performance<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9266 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance.jpg\" alt=\"Arista 7050QX-32S Performance\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Performance.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>Arista 7050QX-32S performance comes down to three numbers: total capacity, port-to-port latency, and how the shared buffer absorbs traffic bursts. Here is how each one behaves in production.<\/p>\n<h3>\u00b7 Arista 7050QX-32S Throughput<\/h3>\n<p>Total switching capacity reaches 2.56 Tbps, which means all 32 QSFP+ ports can run at 40GbE line rate at the same time. The forwarding engine handles 1.44 billion packets per second, so small-packet workloads such as DNS, VoIP signalling, and microservice calls do not hit a packet-rate limit before the bandwidth limit. Arista rates these figures for traffic with an average packet size above 200 bytes.<\/p>\n<h3>\u00b7 Arista 7050QX-32S Latency<\/h3>\n<p>Port-to-port latency ranges from 550 to 650 nanoseconds in cut-through mode. That sub-microsecond figure matters for financial trading, HPC message passing, and distributed databases where every hop adds delay.<\/p>\n<h3>\u00b7 Buffering and Congestion Visibility<\/h3>\n<p>All ports share the 12MB buffer, and Dynamic Buffer Allocation can assign up to 6.7MB to a single congested port. LANZ (Latency Analyzer) reports microbursts in real time, so you can find a noisy server before users notice slow storage or application timeouts. Overall, forwarding performance stays consistent even when several servers burst at once.<\/p>\n<\/div><div class=\"fusion-text fusion-text-6\"><h2><span lang=\"en-PK\">Arista 7050QX-32S EOS Software and Automation<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9267 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation.jpg\" alt=\"Arista 7050QX-32S EOS Software and Automation\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-EOS-Software-and-Automation.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>Arista&#8217;s EOS operating system is a major reason engineers choose this platform. EOS runs on a Linux base with a single software image across Arista switches, and each process runs in its own protected memory space, which lets the system recover from many software faults without a reboot.<\/p>\n<ol>\n<li><strong>MLAG<\/strong>: Dual-home servers to two switches for active-active redundancy without spanning tree blocking.<\/li>\n<li><strong>VXLAN<\/strong>: Stretch Layer 2 segments across a routed fabric for VM mobility and multi-tenant networks.<\/li>\n<li><strong>Automation<\/strong>: eAPI, Zero Touch Provisioning, and Cloud Vision support help teams manage configurations with scripts and Ansible.<\/li>\n<li><strong>Visibility<\/strong>: LANZ, sFlow, and VM Tracer show congestion and virtual machine placement in one place.<\/li>\n<\/ol>\n<p>Before you deploy, check the installed release. EOS 4.28 is the last software train that supports this platform, because EOS 4.29 and later drop the 7050X Series.<\/p>\n<h2>End-of-Life Status and Support Timeline<\/h2>\n<p>Arista announced the end of sale for the DCS-7050QX-32S on December 13, 2021. The milestones below come from Arista&#8217;s official end-of-sale notice, and buyers should factor them into every purchase decision.<\/p>\n<p><!-- wp:table {\"className\":\"is-style-stripes\"} --><\/p>\n<figure class=\"wp-block-table is-style-stripes\">\n<table>\n<thead>\n<tr>\n<th>Milestone<\/th>\n<th>Date<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>End-of-sale announcement<\/strong><\/td>\n<td>December 13, 2021<\/td>\n<\/tr>\n<tr>\n<td><strong>Last day to order from Arista<\/strong><\/td>\n<td>December 13, 2022<\/td>\n<\/tr>\n<tr>\n<td><strong>Last day to add new service contracts<\/strong><\/td>\n<td>December 13, 2023<\/td>\n<\/tr>\n<tr>\n<td><strong>Last day for software bug fixes<\/strong><\/td>\n<td>March 20, 2025<\/td>\n<\/tr>\n<tr>\n<td><strong>Last day for 24&#215;7 TAC support and hardware RMA<\/strong><\/td>\n<td>December 13, 2025<\/td>\n<\/tr>\n<tr>\n<td><strong>End of life<\/strong><\/td>\n<td>December 13, 2025<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:table --><\/p>\n<p>The switch works exactly as it did before these dates, but support now comes from your reseller rather than Arista. EOS 4.28 is the final software train for the platform, so plan your own patching and security reviews. Arista&#8217;s recommended replacements are the <a href=\"https:\/\/directmacro.com\/arista-dcs-7050cx3-32s-r.html\">7050CX3-32S<\/a> and 7050CX3M-32S, which offer higher performance, better scale, and lower power.<\/p>\n<ul>\n<li><strong>Keep Spares<\/strong>: Stock one tested spare for every pair of switches, since Arista RMA replacement is no longer available.<\/li>\n<li><strong>Lock Down Management<\/strong>: Keep management interfaces on an isolated network, apply control-plane ACLs, and disable services you do not use.<\/li>\n<li><strong>Choose Roles Carefully<\/strong>: Use the switch for internal leaf, storage, backup, and lab networks rather than internet-facing edge roles.<\/li>\n<li><strong>Plan the Refresh<\/strong>: Budget a 25\/100GbE upgrade cycle and move these switches into lower-risk pods when that time comes.<\/li>\n<\/ul>\n<h2>Who Should Buy the Arista 7050QX-32S?<\/h2>\n<p>In 2026 and 2027, the DCS-7050QX-32S-R remains a smart buy for teams that need affordable, proven 40GbE capacity now and plan to refresh later. It fits best if you are one of these buyers:<\/p>\n<ol>\n<li><strong>Data Center Teams on 10\/40GbE<\/strong>: Organizations with 10GbE or 40GbE server NICs that need a reliable leaf or small spine at a low cost per port.<\/li>\n<li><strong>Arista Shops<\/strong>: Teams already running Arista EOS that want matching spares or expansion without retraining staff.<\/li>\n<li><strong>Labs and Training Environments<\/strong>: Engineers building leaf-spine, VXLAN, or EVPN labs on real <a href=\"https:\/\/directmacro.com\/\">enterprise hardware<\/a>.<\/li>\n<li><strong>Latency-Sensitive Workloads<\/strong>: Trading, HPC, and analytics clusters that benefit from sub-microsecond switching.<\/li>\n<\/ol>\n<h2>Who Shouldn&#8217;t Buy It?<\/h2>\n<p>This switch is the wrong choice if your roadmap needs 25\/100GbE, active Arista support, or quiet, compact hardware. Skip it in these situations:<\/p>\n<ol>\n<li><strong>25\/100GbE Planners<\/strong>: Buyers moving to 25GbE servers and 100GbE uplinks should consider Arista&#8217;s official replacement, the 7050CX3-32S, or the 7060CX family.<\/li>\n<li><strong>Small Offices<\/strong>: Branch sites that need PoE, copper access ports, or quiet desktop gear will find this switch loud and oversized.<\/li>\n<li><strong>Teams Needing OEM Support<\/strong>: If your policy requires active vendor support contracts, note that Arista TAC support and RMA for this model ended on December 13, 2025.<\/li>\n<\/ol>\n<\/div><div class=\"fusion-text fusion-text-7\"><h2>Is the Arista 7050QX-32S Good for a Home Lab?<\/h2>\n<p>Yes, with a few caveats. Home lab users love the DCS-7050QX-32S-R because refurbished units bring real 40GbE to Ceph, Proxmox, and NAS storage at a low cost per port. EOS behaves exactly like production Arista gear, so every skill you build in the lab carries over to your day job.<\/p>\n<p>Plan for the trade-offs. Data center fans run loud, the switch draws about 150W around the clock, and every link needs QSFP+ optics, DAC cables, or breakout cables.<\/p>\n<p>Place it in a garage, basement rack, or ventilated closet, and use the RJ-45 console port for first setup. If you need a quiet switch under your desk, choose a small fanless 10GbE switch instead.<\/p>\n<h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Arista 7050QX-32S Use Cases: Virtualization, Hosting and Databases<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9268 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases.jpg\" alt=\"Arista 7050QX-32S Use Cases\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Use-Cases.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>The most common Arista 7050QX-32S use cases fall into three groups: virtualization, hosting, and database or storage networks. Each one benefits from the same mix of density, low latency, and EOS automation.<\/p>\n<h3>\u00b7\u00a0 Is the Arista 7050QX-32S Suitable for Virtualization?<\/h3>\n<p>Yes. VMware vSphere, Proxmox, and Hyper-V clusters generate heavy east-west traffic from vMotion, replication, and storage. With VXLAN, MLAG, and VM Tracer, the switch gives each host 40GbE or 4 x 10GbE breakout links with redundancy and visibility into where VMs live. VM Tracer also integrates with VMware vSphere to discover VMs automatically and adjust VLAN segmentation as workloads move.<\/p>\n<h3>\u00b7\u00a0 Is the Arista 7050QX-32S Suitable for Hosting?<\/h3>\n<p>Yes, for web hosting, VPS, and colocation providers that need high port density at a low cost. Wire-speed Layer 3 routing, BGP, and ACLs let you build routed leaf-spine pods. Full internet routing tables, however, belong on a dedicated edge router.<\/p>\n<h3>\u00b7\u00a0 Is the Arista 7050QX-32S Suitable for Databases?<\/h3>\n<p>Yes. Clustered databases such as SQL Server Always On, Oracle RAC, PostgreSQL replicas, and Cassandra benefit from low latency and steady throughput. The shared buffer and LANZ help control microbursts during replication and backup windows, which are among the most demanding workloads for this 40GbE switch.<\/p>\n<h2>How Much RAM Makes Sense?<\/h2>\n<p>Start with the switch itself. The DCS-7050QX-32S-R ships with 4GB of fixed DRAM, which comfortably runs EOS, routing protocols, and on-box scripts. You cannot upgrade it, and most deployments never need to.<\/p>\n<p>The real RAM decision sits with the <a href=\"https:\/\/directmacro.com\/blog\/post\/dell-poweredge-r350-review\">servers you connect<\/a>. Fast 40GbE links only pay off when hosts have <a href=\"https:\/\/directmacro.com\/blog\/post\/server-memory-guide-ddr4-vs-ddr5-ecc-ram\">enough memory<\/a> to keep data moving, so plan 256GB to 512GB per virtualization host.<\/p>\n<p>Database servers usually need 128GB to 1TB, depending on working set size, while web and hosting nodes run well with 64GB to 256GB. Size <a href=\"https:\/\/directmacro.com\/memory\/server.html\">server memory<\/a> first, and the switch will deliver the throughput you paid for.<\/p>\n<h2>Which Storage Configuration Makes Sense?<\/h2>\n<p>On the switch, 4GB of flash holds EOS images and configuration files. The optional 120GB SSD stores logs, packet captures, and LANZ history, but Arista fits it only on SSD-equipped -D units, not on the -R model.<\/p>\n<p>On the network side, 40GbE pairs well with all-flash iSCSI, NFS, and Ceph storage. Each 40GbE port carries four times the bandwidth of a 10GbE link, so backup and replication windows shrink.<\/p>\n<p>For the best results, put storage traffic on dedicated VLANs or VRFs, enable jumbo frames end to end, and dual-home every storage node with MLAG so a single switch failure does not take storage offline.<\/p>\n<\/div><div class=\"fusion-text fusion-text-8\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">What Networking Configuration Should Buyers Consider?<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9269 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1.jpg\" alt=\"Networking Configuration\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Networking-Configuration-1.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>A successful Arista 7050QX-32S deployment starts with three decisions: the fabric role, the optics plan, and the airflow direction.<\/p>\n<h3>\u00b7\u00a0 Arista 7050QX-32S Leaf Spine Design<\/h3>\n<p>In an Arista 7050QX-32S leaf spine design, a common leaf layout uses 24 QSFP+ ports broken out to 96 x 10GbE server links, with 8 x 40GbE uplinks to the spine. As a compact spine, the switch can connect up to 32 leaf switches at 40GbE. Use eBGP or OSPF for the underlay, and add EVPN-VXLAN for the overlay where your EOS release supports it. This leaf-spine approach scales out simply by adding more leaf pairs. Arista&#8217;s datasheet shows two-tier 7050QX leaf-spine designs with modular 7508E spines scaling to more than 110,000 10GbE servers.<\/p>\n<h3>\u00b7 Optics, Cables, and Breakouts<\/h3>\n<p>Use <a href=\"https:\/\/directmacro.com\/cables-adapters\/cables.html\">QSFP+ DAC cables<\/a> for in-rack links, <a href=\"https:\/\/directmacro.com\/finisar-ftl410qd2c.html\">40GBASE-SR4<\/a> or <a href=\"https:\/\/directmacro.com\/finisar-ftl4c1qe1l.html\">LR4 optics<\/a> for longer runs, and QSFP-to-4xSFP+ breakout cables for 10GbE servers. Remember that the four SFP+ ports share the first QSFP+ port, so plan port maps carefully.<\/p>\n<p>Arista&#8217;s datasheet lists these supported optics and cables for the 7050QX-32S:<\/p>\n<p><!-- wp:table {\"className\":\"is-style-stripes\"} --><\/p>\n<figure class=\"wp-block-table is-style-stripes\">\n<table>\n<thead>\n<tr>\n<th>Optic or Cable<\/th>\n<th>Port<\/th>\n<th>Reach<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>40GBASE-CR4 DAC<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>0.5 m to 5 m<\/td>\n<\/tr>\n<tr>\n<td><strong>QSFP+ to 4 x SFP+ breakout DAC<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>0.5 m to 5 m<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-AOC<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>3 m to 100 m<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-SR4<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>100 m (OM3) \/ 150 m (OM4)<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-XSR4<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>300 m (OM3) \/ 400 m (OM4)<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-SRBD<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>100 m (OM3) \/ 150 m (OM4)<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-UNIV<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>150 m (OM3\/OM4) \/ 500 m (SMF)<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-LR4<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>10 km<\/td>\n<\/tr>\n<tr>\n<td><strong>40GBASE-ER4<\/strong><\/td>\n<td>QSFP+<\/td>\n<td>40 km<\/td>\n<\/tr>\n<tr>\n<td><strong>10GBASE-SR<\/strong><\/td>\n<td>SFP+<\/td>\n<td>300 m (OM3) \/ 400 m (OM4)<\/td>\n<\/tr>\n<tr>\n<td><strong>10GBASE-LR<\/strong><\/td>\n<td>SFP+<\/td>\n<td>10 km<\/td>\n<\/tr>\n<tr>\n<td><strong>1GbE SX\/LX and 100\/1000BASE-T<\/strong><\/td>\n<td>SFP+<\/td>\n<td>Supported<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:table --><\/p>\n<h3>\u00b7 DCS-7050QX-32S-R Rear-to-Front Airflow<\/h3>\n<p>The DCS-7050QX-32S-R rear-to-front airflow version pulls cool air in at the power supply side and exhausts it from the port side. Order it only if the switch ports face your hot aisle. If ports face the cold aisle, choose the -F model with front-to-rear fans and PSUs. Mixing airflow directions in one rack raises inlet temperatures and shortens component life. Arista rates the switch for 0 to 40\u00b0C (32 to 104\u00b0F) operating temperature and 5 to 95% relative humidity, so check inlet temperatures after installation.<\/p>\n<\/div><div class=\"fusion-text fusion-text-9\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Setup Notes: Console Access, First Boot, and Noise<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9270 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access.jpg\" alt=\"Console Access\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Console-Access.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>Specification sheets rarely cover what happens when the switch arrives. These practical notes help a first Arista 7050QX-32S deployment go smoothly, whether the unit is headed to a production rack or a lab bench.<\/p>\n<ol>\n<li>Console Access: Use the RJ-45 serial console port with a standard console cable at 9600 baud, 8N1. The USB port is for flash drives that hold EOS images and configuration backups, not for a serial console.<\/li>\n<li><strong>Zero Touch Provisioning<\/strong>: A switch with no startup configuration boots into Zero Touch Provisioning and waits for a provisioning server. Run zero touch cancel from the console to configure it by hand; the switch reloads once.<\/li>\n<li><strong>Management Port<\/strong>: Give the Management1 port its own address, ideally in a dedicated management VRF, so out-of-band access survives changes to the data fabric.<\/li>\n<li><strong>Hardware Verification<\/strong>: Run show version, show inventory, show environment power, and show environment cooling to confirm the EOS release, power supplies, fans, and airflow direction.<\/li>\n<li><strong>Optics Check<\/strong>: Run show interfaces transceiver after cabling. If EOS does not recognize a third-party optic, confirm that the vendor coded it for Arista before replacing it.<\/li>\n<li><strong>Noise and Placement<\/strong>: The fans are very loud at startup and stay noticeable under load. Install the switch in a server room, data center, or closed rack, never in an office or living space.<\/li>\n<\/ol>\n<h2>Arista 7050QX-32S Price and Total Cost of Ownership<\/h2>\n<p>This Arista 7050QX-32S review treats price as part of the full package. Refurbished pricing varies widely with condition, included optics, licenses, and warranty, so compare complete offers rather than headline prices. Check the current price on the Direct Macro product page, or request a bulk quote for multiple units.<\/p>\n<p>Arista rates the 7050QX-32S at about 150W typical and 302W maximum, or under 5W per 40GbE port, and its 500W power supplies are 93% efficient (Platinum rated). Running around the clock, 150W adds up to about 1,314 kWh per year. At $0.15 per kWh, that is roughly $197 per year in electricity before cooling.<\/p>\n<p>The bigger savings come from purchase price and density. One 1RU switch can replace several older 10GbE switches, which frees rack space and reduces cabling and power. The real costs to budget are QSFP+ optics or DAC cables, at least one spare unit, and a reseller warranty, since Arista support has ended.<\/p>\n<p>Beyond the hardware, budget for these ongoing costs:<\/p>\n<ul>\n<li><strong>Feature Licenses<\/strong>: BGP, OSPF, VXLAN, ZTP, and LANZ sit under separate Group 2 licenses, so confirm which licenses the unit carries before you plan the design.<\/li>\n<li><strong>Optics and Cables<\/strong>: QSFP+ DACs, breakout cables, and SR4 or LR4 optics often cost as much as the switch across a full rack.<\/li>\n<li><strong>Spare Fans and Power Supplies<\/strong>: Keep FAN-7000-R and PWR-500AC-R spares on hand, since Arista RMA replacement has ended.<\/li>\n<li><strong>Warranty and Support<\/strong>: Compare reseller warranty length, advance replacement terms, and testing reports, because Arista TAC is no longer available.<\/li>\n<li><strong>Power and Cooling<\/strong>: Plan for 150W typical and up to 302W per switch, plus the cooling load in a 24\/7 rack.<\/li>\n<\/ul>\n<\/div><div class=\"fusion-text fusion-text-10\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Is a Refurbished Arista 7050QX-32S Worth Considering?<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9271 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering.jpg\" alt=\"Is a Refurbished Arista 7050QX-32S Worth Considering\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Is-a-Refurbished-Arista-7050QX-32S-Worth-Considering.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>For this switch, yes, and that is the clearest finding of this Arista 7050QX-32S review. A refurbished unit delivers the same 2.56 Tbps fabric as a new one at a much lower price, and the platform&#8217;s mature software means few surprises. Choose a supplier that tests every port, resets the configuration, includes both power supplies and all fans, and backs the hardware with a warranty. For broader advice, read our <a href=\"https:\/\/directmacro.com\/blog\/post\/network-switch-things-you-need-to-know-before-buying\">network switch buying guide<\/a>.<\/p>\n<p>Keep in mind that Arista&#8217;s original one-year limited hardware warranty expired long ago on these units, so the reseller&#8217;s warranty is the coverage that matters.<\/p>\n<p><strong>Want Proof Before You Buy? <\/strong>Ask our team for the test results on the exact unit you plan to order, including port, fan, power supply, and temperature checks.<\/p>\n<\/div><div class=\"fusion-text fusion-text-11\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">What to Check Before Purchasing?<\/span><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9272 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1.jpg\" alt=\"What to Check Before Purchasing\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/What-to-Check-Before-Purchasing-1.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>Refurbished buyers save the most when they verify the details first. Check these points on every DCS-7050QX-32S-R before you place your order:<\/p>\n<ol>\n<li><strong>Airflow Direction:<\/strong> Confirm the -R suffix, fan modules, and PSU airflow labels all match your rack layout.<\/li>\n<li><strong>Power Supplies<\/strong>: Verify two working 500W PSUs and the correct C13 power cords for redundant power.<\/li>\n<li><strong>EOS Version and Licenses<\/strong>: Check the installed EOS release and which Group 2 feature licenses are active, such as LIC-FIX-2-E for BGP and OSPF, LIC-FIX-2-V for VXLAN, and LIC-FIX-2-Z for ZTP and LANZ.<\/li>\n<li><strong>Port and Fan Health<\/strong>: Ask for test reports covering all QSFP+ and SFP+ ports, fan status, and temperature readings.<\/li>\n<li><strong>Optics Compatibility<\/strong>: Budget for QSFP+ optics or DACs, and confirm third-party optics behavior on your EOS release.<\/li>\n<li><strong>Rack Kit and Warranty<\/strong>: Make sure the seller includes rails and that the warranty covers the full unit.<\/li>\n<li><strong>Spare Parts<\/strong>: Confirm that spare fan modules (FAN-7000-R) and power supplies (PWR-500AC-R) are rear-to-front versions, since mixing -F and -R parts fight the airflow inside the chassis.<\/li>\n<li><strong>Buy With Confidence<\/strong>: Send this checklist to the Direct Macro sales team, and we will confirm each item on the exact DCS-7050QX-32S-R you order before it ships.<\/li>\n<\/ol>\n<\/div><div class=\"fusion-text fusion-text-12\"><h2>Arista 7050QX-32S vs Similar Enterprise Switches<\/h2>\n<p>Here is how the Arista 7050QX-32S data center switch compares with <a href=\"https:\/\/directmacro.com\/networking-devices\/switches\/network-switches\/aristanetworks.html\">other 32-port 40GbE options<\/a> in the same class.<\/p>\n<p><!-- wp:table {\"className\":\"is-style-stripes\"} --><\/p>\n<figure class=\"wp-block-table is-style-stripes\">\n<table>\n<thead>\n<tr>\n<th>Switch<\/th>\n<th>Ports<\/th>\n<th>Throughput<\/th>\n<th>Best For<\/th>\n<th>Key Difference vs 7050QX-32S<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Arista 7050QX-32S<\/strong><\/td>\n<td>32 x QSFP+, 4 x SFP+<\/td>\n<td>2.56 Tbps<\/td>\n<td>10\/40GbE leaf or compact spine<\/td>\n<td>Baseline: 12MB buffer, 4GB DRAM, 64-way ECMP, EOS 4.28 final<\/td>\n<\/tr>\n<tr>\n<td><strong>Arista 7050QX2-32S<\/strong><\/td>\n<td>32 x QSFP+, 4 x SFP+<\/td>\n<td>2.56 Tbps<\/td>\n<td>Buyers who want more buffer<\/td>\n<td>16MB buffer, 8GB DRAM, 128-way ECMP, 129W typical power<\/td>\n<\/tr>\n<tr>\n<td><strong>Cisco Nexus 3132Q<\/strong><\/td>\n<td>32 x QSFP+, 4 x SFP+<\/td>\n<td>2.56 Tbps<\/td>\n<td>Cisco NX-OS environments<\/td>\n<td>Same port density, managed with NX-OS instead of EOS<\/td>\n<\/tr>\n<tr>\n<td><strong>Dell S6000-ON<\/strong><\/td>\n<td>32 x QSFP+<\/td>\n<td>2.56 Tbps<\/td>\n<td>Open networking<\/td>\n<td>ONIE support for third-party network operating systems<\/td>\n<\/tr>\n<tr>\n<td><strong>Juniper QFX5100-24Q<\/strong><\/td>\n<td>24 x QSFP+, plus 2 expansion slots<\/td>\n<td>2.56 Tbps with expansion modules<\/td>\n<td>Junos fabrics<\/td>\n<td>Modular expansion and Virtual Chassis support<\/td>\n<\/tr>\n<tr>\n<td><strong>Arista 7050CX3-32S<\/strong><\/td>\n<td>32 x QSFP100, 2 x SFP+<\/td>\n<td>6.4 Tbps<\/td>\n<td>Arista&#8217;s official replacement<\/td>\n<td>100GbE ports and current EOS software support<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p><!-- \/wp:table --><\/p>\n<p>Compared with the Nexus and QFX options, the Arista stands out for its single EOS image, programmable APIs, and LANZ visibility. The Dell S6000-ON wins on NOS choice, while the 7050CX3-32S is Arista&#8217;s recommended upgrade path once 100GbE becomes a requirement. This makes the Arista DCS-7050QX-32S-R review outcome clear: it is the value leader for 40GbE.<\/p>\n<\/div><div class=\"fusion-text fusion-text-13\"><h2>Arista 7050QX-32S vs 7050QX2-32S: What Changed?<\/h2>\n<p>Many buyers compare the original 7050QX-32S with the 7050QX2-32S refresh, since both appear on the refurbished market with the same 32 x QSFP+ and 4 x SFP+ front panel. For this Arista 7050QX-32S review, we compared both models in Arista&#8217;s datasheet, which lists these differences:<\/p>\n<ul>\n<li><strong>Memory<\/strong>: System DRAM doubles from 4GB on the 7050QX-32S to 8GB on the 7050QX2-32S.<\/li>\n<li><strong>Packet Buffer<\/strong>: The shared buffer grows from 12MB to 16MB for more demanding, bursty environments.<\/li>\n<li><strong>Power<\/strong>: Typical and maximum draw fall from 150W and 302W to 129W and 283W.<\/li>\n<li><strong>ECMP Scale<\/strong>: Equal-cost multipath grows from 64-way with 1K groups to 128-way with 2K groups.<\/li>\n<li><strong>ACL Capacity<\/strong>: Ingress ACLs rise from 4K to up to 11K entries, while egress ACLs drop from 1K to 756.<\/li>\n<li><strong>Software<\/strong>: The minimum EOS release moves from 4.14.0 to 4.18.0, and OpenFlow is not supported on the 7050QX2-32S.<\/li>\n<\/ul>\n<p>Both models share the same end-of-software-support notice, so EOS 4.28 is the last train for either one. If you already run 7050QX-32S switches, buying more of the same model keeps spares and configurations identical. If you are starting fresh and the price gap is small, the 7050QX2-32S offers more buffer and memory headroom.<\/p>\n<p><strong>Further Reading:<\/strong><\/p>\n<ul>\n<li><strong><a href=\"https:\/\/directmacro.com\/blog\/post\/cisco-c9200l-48p-4x-a-review-48-port-poe-switch-4x10g-uplinks\" target=\"_blank\" rel=\"noopener\">Cisco C9200L-48P-4X-A Review<\/a><\/strong><\/li>\n<li><strong><a href=\"https:\/\/directmacro.com\/blog\/post\/dell-1knc8-review-s4048t-on-48-port-10gbe-switch\" target=\"_blank\" rel=\"noopener\">Dell 1KNC8 Review<\/a><\/strong><\/li>\n<\/ul>\n<h2>Arista 7050QX-32S Deployment Best Practices<\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-9273 size-full\" src=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment.jpg\" alt=\"Arista 7050QX-32S Deployment\" width=\"602\" height=\"318\" srcset=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment-200x106.jpg 200w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment-300x158.jpg 300w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment-400x211.jpg 400w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment-600x317.jpg 600w, https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Deployment.jpg 602w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/p>\n<p>A clean rollout takes a few hours per switch pair and prevents most support issues later. Follow these steps for every Arista 7050QX-32S deployment:<\/p>\n<h3>Step 1. Plan Airflow and Power<\/h3>\n<p>Confirm the -R fans and power supplies match your hot aisle, and connect each PSU to a separate PDU or <a href=\"https:\/\/directmacro.com\/power-supplies-power-protection.html\">UPS circuit<\/a>.<\/p>\n<h3>Step 2. Rack the Switch<\/h3>\n<p>Use the tool-less rail kit for four-post racks or the 2-post kit for telco racks, and keep the switch within its 0 to 40\u00b0C operating range.<\/p>\n<h3>Step 3. Standardize on EOS 4.28<\/h3>\n<p>Load the latest EOS 4.28 maintenance release on every switch before production so features and bug fixes match across the fabric.<\/p>\n<h3>Step 4. Secure Management<\/h3>\n<p>Place Management1 in a dedicated management VRF, enable TACACS+ or RADIUS with SSHv2, disable Telnet, and apply control-plane ACLs.<\/p>\n<h3>Step 5. Build the Fabric<\/h3>\n<p>Pair leaf switches with MLAG for dual-homed servers, run an eBGP underlay with ECMP to the spines, and add VXLAN only where you hold the license.<\/p>\n<h3>Step 6. Validate Optics and Breakouts<\/h3>\n<p>Configure 4 x 10GbE breakouts where needed, then confirm link state and optical power with <strong>show interfaces transceiver<\/strong>.<\/p>\n<h3>Step 7. Monitor and Back Up<\/h3>\n<p>Enable LANZ, sFlow, SNMPv3, and remote syslog, and copy the running configuration off the switch after every change.<\/p>\n<h2>What Does Direct Macro Recommend?<\/h2>\n<p>Based on this Arista 7050QX-32S review and our Arista DCS-7050QX-32S-R review checklist, Direct Macro recommends the switch for teams that run 10GbE or 40GbE servers and want enterprise-grade performance at a refurbished price. Most buyers deploy it in one of these three setups, each built with the same DCS-7050QX-32S-R switch, plus a spares plan:<\/p>\n<ul>\n<li><strong>10GbE Server Leaf<\/strong>: Two DCS-7050QX-32S-R switches in an MLAG pair, each with 24 QSFP+ ports broken out to 96 x 10GbE and 8 x 40GbE ports left for uplinks and the MLAG peer link. Ideal for racks of dual-homed 10GbE servers.<\/li>\n<li><strong>Compact 40GbE Spine<\/strong>: Two switches running eBGP with ECMP, each connecting up to 32 leaf switches at 40GbE. Ideal for small and midsize leaf-spine fabrics that do not need 100GbE yet.<\/li>\n<li><strong>Storage and Lab Pod<\/strong>: One or two switches with native 40GbE links to all-flash iSCSI, NFS, or Ceph nodes, jumbo frames end to end, and PFC for lossless storage traffic. Ideal for backup networks, test labs, and training.<\/li>\n<li><strong>Spares and Upgrade Path<\/strong>: Keep one tested spare for every pair, plan a move to 25\/100GbE when you refresh server NICs, and then reuse these switches in labs or edge pods.<\/li>\n<\/ul>\n<p>If your roadmap stays on 10\/40GbE for the next few years, the Arista 7050QX-32S 40GbE switch remains one of the best-value fabrics you can buy.<\/p>\n<p><strong>Further Reading:<\/strong> Explore our guide to the <a href=\"https:\/\/directmacro.com\/blog\/post\/best-network-switches\">best network switches<\/a> for business and data center networks.<\/p>\n<\/div><div class=\"fusion-text fusion-text-14\"><h2><span lang=\"en-PK\" style=\"font-family: 'Arial Black',sans-serif;\">Final Thoughts<\/span><\/h2>\n<p>This Arista 7050QX-32S review comes down to one point: the DCS-7050QX-32S-R is one of the fastest ways to add dense, low-latency 40GbE to a rack without paying for a new 100GbE platform. It delivers 2.56 Tbps of wire-speed switching, sub-microsecond latency, and proven EOS automation. Despite its end-of-life status, it still has years of useful work left in leaf, storage, lab, and spare roles.<\/p>\n<p>Buy in pairs or in bulk: two switches give you MLAG redundancy, a tested spare replaces the retired Arista RMA service, and matching units keep EOS versions, optics, and airflow consistent.<\/p>\n<p><strong>Ready to buy?<\/strong> <a href=\"https:\/\/directmacro.com\/contact\">Contact<\/a> the Direct Macro team for a <a href=\"https:\/\/directmacro.com\/bulk-quote\">bulk quote<\/a> on tested, warranty-backed DCS-7050QX-32S-R switches, matching optics, and spare parts.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<ol>\n<li><strong> What is the Arista DCS-7050QX-32S-R?<\/strong><\/li>\n<\/ol>\n<p>It is a 1RU Arista 7050QX-32S data center switch with 32 x 40GbE QSFP+ ports, 4 x 10GbE SFP+ ports, dual 500W AC power supplies, and rear-to-front airflow.<\/p>\n<ol start=\"2\">\n<li><strong> What is the Arista 7050QX-32S throughput and latency?<\/strong><\/li>\n<\/ol>\n<p>Arista 7050QX-32S throughput is 2.56 Tbps with 1.44 billion packets per second, and Arista 7050QX-32S latency starts at 550 nanoseconds in cut-through mode.<\/p>\n<ol start=\"3\">\n<li><strong> Does the Arista 7050QX-32S support 10GbE?<\/strong><\/li>\n<\/ol>\n<p>Yes. You can split up to 24 QSFP+ ports into 4 x 10GbE each for 96 x 10GbE ports, and the four SFP+ ports support 1GbE and 10GbE.<\/p>\n<ol start=\"4\">\n<li><strong> What does the -R in DCS-7050QX-32S-R mean?<\/strong><\/li>\n<\/ol>\n<p>The -R suffix means rear-to-front airflow. Choose it when the switch ports face the hot aisle, and choose the -F model when ports face the cold aisle.<\/p>\n<ol start=\"5\">\n<li><strong> Is the Arista 7050QX-32S good for leaf spine networks?<\/strong><\/li>\n<\/ol>\n<p>Yes. Arista 7050QX-32S leaf spine designs commonly use it as a 10\/40GbE leaf or a compact 40GbE spine with BGP, MLAG, and VXLAN.<\/p>\n<ol start=\"6\">\n<li><strong> Is a refurbished Arista 7050QX-32S reliable?<\/strong><\/li>\n<\/ol>\n<p>A tested refurbished unit with both power supplies, all fans, verified ports, and a warranty is a reliable, cost-effective choice for production, spares, and labs.<\/p>\n<ol start=\"7\">\n<li><strong> Is the Arista 7050QX-32S end of life?<\/strong><\/li>\n<\/ol>\n<p>Yes. Arista stopped selling it on December 13, 2022, and 24&#215;7 TAC support, hardware RMA, and end of life followed on December 13, 2025. Tested refurbished units are still widely available with reseller warranties.<\/p>\n<ol start=\"8\">\n<li><strong> Which EOS version should I run on the 7050QX-32S?<\/strong><\/li>\n<\/ol>\n<p>EOS 4.28 is the final software train that supports the 7050X Series, because EOS 4.29 and later drop the platform. Run the newest 4.28 release you are entitled to and keep one version across the fabric.<\/p>\n<ol start=\"9\">\n<li><strong> Is the Arista 7050QX-32S loud?<\/strong><\/li>\n<\/ol>\n<p>Yes. Like most 1RU <a href=\"https:\/\/directmacro.com\/networking-devices\/switches.html\">data center switches<\/a>, it uses high-speed fans that are very loud at startup and noticeable under load. Install it in a server room or data center rack, not an office.<\/p>\n<ol start=\"10\">\n<li><strong> Does the Arista 7050QX-32S need licenses for BGP and VXLAN?<\/strong><\/li>\n<\/ol>\n<p>Often, yes. Arista&#8217;s datasheet lists separate Group 2 feature licenses: LIC-FIX-2-E for Enhanced L3 (BGP, OSPF, IS-IS, PIM), LIC-FIX-2-V for VXLAN and VM Tracer, and LIC-FIX-2-Z for ZTP, LANZ, and OpenFlow. Ask the seller which licenses a refurbished unit includes before you buy.<\/p>\n<p>&nbsp;<\/p>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>The Arista 7050QX-32S 40GbE switch delivers 2.56 Tbps and 1.44 billion packets per second across 32 QSFP+ ports in 1RU.<\/p>\n","protected":false},"author":19,"featured_media":9260,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[774],"tags":[821,818,820,819,822],"class_list":["post-9259","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-reviews","tag-40gbe-switch","tag-arista-7050qx-32s","tag-arista-7050x-series","tag-arista-dcs-7050qx-32s-r","tag-data-center-networking"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.8 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Arista 7050QX-32S Review (DCS-7050QX-32S-R)<\/title>\n<meta name=\"description\" content=\"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Arista 7050QX-32S Review: 40GbE Switch Specification and Deployment\" \/>\n<meta property=\"og:description\" content=\"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review\" \/>\n<meta property=\"og:site_name\" content=\"Direct Macro\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-14T18:53:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-14T18:57:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"602\" \/>\n\t<meta property=\"og:image:height\" content=\"318\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Amna Munnawer\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Arista 7050QX-32S Review: 40GbE Switch Specification and Deployment\" \/>\n<meta name=\"twitter:description\" content=\"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Amna Munnawer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"27 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review\"},\"author\":{\"name\":\"Amna Munnawer\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/#\\\/schema\\\/person\\\/af17c6af6d306d0e6d813ce0eb02e422\"},\"headline\":\"Arista 7050QX-32S Review (DCS-7050QX-32S-R): 40GbE Switch Specification and Deployment\",\"datePublished\":\"2026-10-14T18:53:21+00:00\",\"dateModified\":\"2026-10-14T18:57:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review\"},\"wordCount\":8409,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Arista-7050QX-32S-Review.jpg\",\"keywords\":[\"40GbE Switch\",\"Arista 7050QX-32S\",\"Arista 7050X Series\",\"Arista DCS-7050QX-32S-R\",\"Data Center Networking\"],\"articleSection\":[\"Reviews\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review\",\"url\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review\",\"name\":\"Arista 7050QX-32S Review (DCS-7050QX-32S-R)\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Arista-7050QX-32S-Review.jpg\",\"datePublished\":\"2026-10-14T18:53:21+00:00\",\"dateModified\":\"2026-10-14T18:57:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/#\\\/schema\\\/person\\\/af17c6af6d306d0e6d813ce0eb02e422\"},\"description\":\"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#primaryimage\",\"url\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Arista-7050QX-32S-Review.jpg\",\"contentUrl\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/Arista-7050QX-32S-Review.jpg\",\"width\":602,\"height\":318,\"caption\":\"Arista 7050QX-32S Review (DCS-7050QX-32S-R)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/post\\\/arista-7050qx-32s-review#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Arista 7050QX-32S Review (DCS-7050QX-32S-R): 40GbE Switch Specification and Deployment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/\",\"name\":\"Direct Macro\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/#\\\/schema\\\/person\\\/af17c6af6d306d0e6d813ce0eb02e422\",\"name\":\"Amna Munnawer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/litespeed\\\/avatar\\\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277\",\"url\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/litespeed\\\/avatar\\\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277\",\"contentUrl\":\"https:\\\/\\\/directmacro.com\\\/blog\\\/wp-content\\\/litespeed\\\/avatar\\\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277\",\"caption\":\"Amna Munnawer\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Arista 7050QX-32S Review (DCS-7050QX-32S-R)","description":"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review","og_locale":"en_US","og_type":"article","og_title":"Arista 7050QX-32S Review: 40GbE Switch Specification and Deployment","og_description":"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.","og_url":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review","og_site_name":"Direct Macro","article_published_time":"2026-10-14T18:53:21+00:00","article_modified_time":"2026-10-14T18:57:20+00:00","og_image":[{"width":602,"height":318,"url":"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg","type":"image\/jpeg"}],"author":"Amna Munnawer","twitter_card":"summary_large_image","twitter_title":"Arista 7050QX-32S Review: 40GbE Switch Specification and Deployment","twitter_description":"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.","twitter_misc":{"Written by":"Amna Munnawer","Est. reading time":"27 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#article","isPartOf":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review"},"author":{"name":"Amna Munnawer","@id":"https:\/\/directmacro.com\/blog\/#\/schema\/person\/af17c6af6d306d0e6d813ce0eb02e422"},"headline":"Arista 7050QX-32S Review (DCS-7050QX-32S-R): 40GbE Switch Specification and Deployment","datePublished":"2026-10-14T18:53:21+00:00","dateModified":"2026-10-14T18:57:20+00:00","mainEntityOfPage":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review"},"wordCount":8409,"commentCount":0,"image":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#primaryimage"},"thumbnailUrl":"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg","keywords":["40GbE Switch","Arista 7050QX-32S","Arista 7050X Series","Arista DCS-7050QX-32S-R","Data Center Networking"],"articleSection":["Reviews"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#respond"]}]},{"@type":"WebPage","@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review","url":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review","name":"Arista 7050QX-32S Review (DCS-7050QX-32S-R)","isPartOf":{"@id":"https:\/\/directmacro.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#primaryimage"},"image":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#primaryimage"},"thumbnailUrl":"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg","datePublished":"2026-10-14T18:53:21+00:00","dateModified":"2026-10-14T18:57:20+00:00","author":{"@id":"https:\/\/directmacro.com\/blog\/#\/schema\/person\/af17c6af6d306d0e6d813ce0eb02e422"},"description":"Arista 7050QX-32S review covering 40GbE performance, leaf-spine deployment, key specifications, and refurbished buying tips.","breadcrumb":{"@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#primaryimage","url":"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg","contentUrl":"https:\/\/directmacro.com\/blog\/wp-content\/uploads\/2026\/10\/Arista-7050QX-32S-Review.jpg","width":602,"height":318,"caption":"Arista 7050QX-32S Review (DCS-7050QX-32S-R)"},{"@type":"BreadcrumbList","@id":"https:\/\/directmacro.com\/blog\/post\/arista-7050qx-32s-review#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/directmacro.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Arista 7050QX-32S Review (DCS-7050QX-32S-R): 40GbE Switch Specification and Deployment"}]},{"@type":"WebSite","@id":"https:\/\/directmacro.com\/blog\/#website","url":"https:\/\/directmacro.com\/blog\/","name":"Direct Macro","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/directmacro.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/directmacro.com\/blog\/#\/schema\/person\/af17c6af6d306d0e6d813ce0eb02e422","name":"Amna Munnawer","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/directmacro.com\/blog\/wp-content\/litespeed\/avatar\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277","url":"https:\/\/directmacro.com\/blog\/wp-content\/litespeed\/avatar\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277","contentUrl":"https:\/\/directmacro.com\/blog\/wp-content\/litespeed\/avatar\/afc32550a52999d2ac0c88bc30d80fd6.jpg?ver=1793111277","caption":"Amna Munnawer"}}]}},"_links":{"self":[{"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/posts\/9259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/comments?post=9259"}],"version-history":[{"count":10,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/posts\/9259\/revisions"}],"predecessor-version":[{"id":9281,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/posts\/9259\/revisions\/9281"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/media\/9260"}],"wp:attachment":[{"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/media?parent=9259"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/categories?post=9259"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/directmacro.com\/blog\/wp-json\/wp\/v2\/tags?post=9259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}