** Image may not exactly match product **
210-AGMQ - Dell EMC S6010-ON 32-Port 40GbE QSFP+ L3 Switch
Availabilty: In stock
Refurbished
Seeking a large quantity of 210-AGMQ, or have a target price in mind? Contact us at (855) 483-7810 or simply Request a Bulk Quote. Our sales team will promptly respond with a discounted price tailored to your needs.
PAYMENT
Dell EMC Networking S6010-ON 1U ToR switch with 32 QSFP+ 40GbE ports, 2.56Tbps switching capacity, sub-600ns latency, L2/L3 routing, VXLAN gateway, and ONIE support.
The 210-AGMQ is the Dell part number for the Dell EMC Networking S6010-ON, a 1RU high-density Top-of-Rack (ToR) switch designed for modern data center fabrics. It provides 32 line-rate 40 Gigabit Ethernet QSFP+ ports (configurable as 96x10GbE plus 8x40GbE) and delivers up to 2.56Tbps of non-blocking switching I/O bandwidth with sub-600ns cut-through latency. As part of Dell's disaggregated 'Open Networking' strategy, the S6010-ON supports ONIE (Open Network Install Environment), allowing it to run Dell EMC Networking OS9 or SmartFabric OS10, or third-party network operating systems. It supports Layer 2/Layer 3 switching with QoS, IPv4/IPv6, VRF, OSPF, BGP, VLT/mVLT multi-chassis link aggregation, and VXLAN gateway functionality, making it suitable for leaf-spine data center fabrics, cloud, and virtualization deployments.
- Manufacturer: Dell EMC
- Product Family: Dell EMC Networking S-Series
- Product Series: S6010-ON
- Model: S6010-ON
- Product Type: 1RU Top-of-Rack (ToR) Layer 2/3 Ethernet Switch
- Ports: 32 x 40GbE QSFP+ line-rate ports (configurable as 96 x 10GbE plus 8 x 40GbE)
- Management Ports: 1 RJ45 console/management port (RS232), 1 USB 2.0 Type A storage port, 1 USB 2.0 Type B console port
- Switching Capacity: Up to 2.56 Tbps switching I/O bandwidth, full duplex
- Latency: Sub 600ns cut-through latency
- Routing Protocols: OSPF, BGP, IPv4 VRF, IPv6
- L2 Features: Virtual Link Trunking (VLT) and multiple VLT (mVLT) multi-chassis link aggregation
- Overlay Support: VXLAN gateway functionality for bridging virtualized and non-virtualized networks
- Operating System: Dell EMC Networking OS9 (default); supports Dell EMC SmartFabric OS10 and other NOS via ONIE
- Boot/Install Environment: Open Network Install Environment (ONIE) for zero-touch NOS installation
- Power Supply: 2 x redundant, hot-swappable 460W AC PSUs, 100–240 VAC, 50/60 Hz
- DC Power Option: -40.5 VDC to -60 VDC at maximum 15A (DC PSU variant)
- Max Power Consumption: 411 Watts
- Typical Power Consumption: 274 Watts
- PoE: Not supported
- Operating Temperature: 0°C to 45°C (32°F to 113°F)
- Operating Humidity: 10% to 90% RH, non-condensing
- Storage Temperature: -40°C to 70°C (-40°F to 158°F)
- Storage Humidity: 5% to 95% RH, non-condensing
- Dimensions: 1RU, 1.71 x 17.08 x 18.11 inches (43.4 x 434 x 460mm)
- Weight: 16.12 lbs (7.32 kg)
- Mounting: Tool-less ReadyRails mounting kit
- Cooling: Redundant fan modules; airflow I/O-to-PSU or PSU-to-I/O configurations
- Convergence Features: DCB with Priority Flow Control (802.1Qbb), ETS (802.1Qaz), DCBX, iSCSI TLV support, RoCE
- Software Feature: Fastboot for minimal-loss software upgrade on standalone units
- 32 line-rate 40GbE QSFP+ ports for high-density ToR deployments
- Up to 2.56Tbps non-blocking switching fabric with sub-600ns latency
- Flexible port configuration: 32x40GbE or 96x10GbE plus 8x40GbE
- Layer 2 and Layer 3 switching with full IPv4/IPv6 routing support
- VLT and mVLT for multi-chassis link aggregation and L2 multipathing
- VXLAN gateway for bridging virtualized and non-virtualized network segments
- ONIE support enabling choice of Dell EMC OS9, SmartFabric OS10, or third-party NOS
- Redundant, hot-swappable 460W AC power supplies for high availability
- Data Center Bridging (DCB) and RoCE support for converged storage and compute
- Power-efficient operation rated up to 45°C ambient temperature
- Tool-less ReadyRails rack mounting for fast installation
- Fastboot feature for reduced-downtime software upgrades
Designed for high-throughput data center leaf-spine and Top-of-Rack switching architectures.
- Top-of-Rack (ToR) switching in data center leaf-spine fabric designs
- High-density 40GbE server and storage connectivity aggregation
- VXLAN overlay gateway for virtualized cloud and multi-tenant environments
- Converged Ethernet fabrics supporting iSCSI and RoCE storage traffic
- Open networking deployments requiring a choice of network operating system
- Multi-chassis link aggregation (VLT/mVLT) for resilient network core designs
- Enterprise and service provider networks needing L2/L3 routing at scale
- High-density 40GbE port count in compact 1U form
- Ultra-low latency for demanding data center workloads
- Flexible OS choice via ONIE reduces vendor lock-in
- Redundant power for improved uptime and reliability
- Scalable L3 routing simplifies fabric-wide connectivity
- Efficient cooling supports higher-temperature environments
| Interface Type | Details |
|---|---|
| Network Ports | 32 x 40GbE QSFP+ line-rate ports (alternatively 96 x 10GbE plus 8 x 40GbE) |
| Console/Management | 1 x RJ45 console/management port with RS232 signaling |
| USB Storage | 1 x USB 2.0 Type A storage port |
| USB Console | 1 x USB 2.0 Type B console port |
- Form Factor: 1RU rack-mountable
- Dimensions: 1.71 x 17.08 x 18.11 inches (43.4 x 434 x 460mm)
- Weight: 16.12 lbs (7.32 kg)
- Rack Mounting: Tool-less ReadyRails kit
Per official Dell documentation, the S6010-ON (210-AGMQ) is validated for use with the following optics and accessories:
- 40GbE LM4 Duplex QSFP+ transceivers (150m MMF / 1km SMF reach)
- 40GbE SM4 Duplex QSFP+ transceivers (220m MMF reach)
- QSFP+ to SFP/SFP+ adapter (QSA) for 1GbE/10GbE connectivity
- MTP to MTP OM3/OM4 fiber cables (3-100 meter lengths)
- 10GbE SFP+ to SFP+ Active Optical Cables (15m reach)
- 40GbE QSFP+ to QSFP+ Active Optical Cables (10m and 40m reach)
- 40GbE QSFP+ MTP to 4x10GbE SFP+ Active Optical Breakout Cables
- 40GbE QSFP+ to 4x10GbE SFP+ Passive Copper Breakout Cables
- Dell EMC Networking OS9 and SmartFabric OS10 network operating systems
- ReadyRails rack mounting kits for standard 19-inch racks
Note: Accessory and optics compatibility is based on the official Dell EMC S6010-ON spec sheet; availability of specific NOS images or optics may vary by Dell region and order configuration.
- Dell EMC S6010-ON switch chassis
- Redundant hot-swappable AC power supply unit(s)
- Fan module(s)
- ReadyRails mounting kit
- Documentation/getting started guide
Q: What product does the MPN 210-AGMQ refer to?
A: 210-AGMQ is the Dell part number for the Dell EMC Networking S6010-ON, a 32-port 40GbE QSFP+ Layer 3 ToR switch, as confirmed by multiple Dell reseller and distributor listings.
Q: How many ports does the S6010-ON (210-AGMQ) provide?
A: It offers 32 line-rate 40GbE QSFP+ ports, which can alternatively be configured as 96 x 10GbE ports plus 8 x 40GbE ports according to the official Dell spec sheet.
Q: What is the switching capacity and latency of this switch?
A: The switch delivers up to 2.56 Tbps of switching I/O bandwidth in full duplex with a cut-through switching fabric offering sub-600ns latency, per the official Dell spec sheet.
Q: Does the S6010-ON support Power over Ethernet (PoE)?
A: No, the switch is not PoE-enabled, as confirmed by third-party distributor documentation citing the official specifications.
Q: What network operating systems can run on the 210-AGMQ?
A: The switch ships with Dell EMC Networking OS9 and, because it supports ONIE (Open Network Install Environment), can also run Dell EMC SmartFabric OS10 or other compatible third-party network operating systems.
Q: What are the power and environmental specifications?
A: It uses redundant, hot-swappable 460W AC power supplies (100-240 VAC), with typical power consumption of 274W and maximum of 411W, and operates in temperatures from 0°C to 45°C per Dell's official documentation.
Q: What is the physical size and weight of the switch?
A: The S6010-ON is a 1RU unit measuring 1.71 x 17.08 x 18.11 inches and weighing 16.12 lbs (7.32 kg), according to the official Dell spec sheet.
Q: Does the switch support advanced data center fabric features like VXLAN and VLT?
A: Yes, it supports VXLAN gateway functionality for bridging virtualized and non-virtualized networks, along with VLT and multiple VLT (mVLT) for multi-chassis link aggregation.